Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biophotonics ; 14(10): e202100124, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34185435

RESUMO

We present an automatic lumen segmentation method using uniqueness of connected region for intravascular optical coherence tomography (IVOCT), which can effectively remove the effect on lumen segmentation caused by blood artifacts. Utilizing the uniqueness of vascular wall on A-lines, we detect the A-lines shared by multiple connected regions, identify connected regions generated by blood artifacts using traversal comparison of connected regions' location, shared ratio and area ratio and then remove all artifacts. We compare these three methods by 216 challenging images with severe blood artifacts selected from clinical 1076 IVOCT images. The metrics of the proposed method are evaluated including Dice index, Jaccard index and accuracy of 94.57%, 90.12%, 98.02%. Compared with automatic lumen segmentation based on the previous morphological feature method and widely used dynamic programming method, the metrics of the proposed method are significantly enhanced, especially in challenging images with severe blood artifacts.


Assuntos
Algoritmos , Tomografia de Coerência Óptica , Artefatos
2.
J Biophotonics ; 14(3): e202000370, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33247508

RESUMO

We present a three-dimensional (3D) spatial reconstruction of coronary arteries based on fusion of intravascular optical coherence tomography (IVOCT) and digital subtraction angiography (DSA). Centerline of vessel in DSA images is exacted by multi-scale filtering, adaptive segmentation, morphology thinning and Dijkstra's shortest path algorithm. We apply the cross-correction between lumen shapes of IVOCT and DSA images and match their stenosis positions to realize co-registration. By matching the location and tangent direction of the vessel centerline of DSA images and segmented lumen coordinates of IVOCT along pullback path, 3D spatial models of vessel lumen are reconstructed. Using 1121 distinct positions selected from eight vessels, the correlation coefficient between 3D IVOCT model and DSA image in measuring lumen radius is 0.94% and 97.7% of the positions fall within the limit of agreement by Bland-Altman analysis, which means that the 3D spatial reconstruction IVOCT models and DSA images have high matching level.


Assuntos
Vasos Coronários , Tomografia de Coerência Óptica , Algoritmos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...